This control panel is suitable with all PLANAR air heaters 12V and 24V.
“Power mode”
(If the external sensor is not connected)
Designed for quickest possible heating of the space;
The heater operates continuously at a set power.
** “Temperature mode”
(If the external sensor
is connected)
Designed to heat the space to the required temperature;
Heat output decreases as the difference between the desired temperature and the temperature in the space decreases.
* “Ventilation mode”
Designed for air circulation in the space.
** “Ventilation during
heating” - function
(If the external sensor
is connected)
Designed to maintain the required temperature in the space;
After the required temperature is reached, the space heating is stopped and space air circulation is performed;
Controls the space temperature; if the temperature drops below the set point, the heater will start in Ventilation mode.
Dimensions: 50 x 36 x 18 mm
* Please note, that PLANAR air heaters with production date 16.11.2016 or older does not support Ventilation mode. You can check your air heaters PLANAR production date on the warranty card.
** Please note, that all PLANAR air heaters need external temperature sensor (assy.1458), so that the "Power mode" and "Ventilation during heating” function would work.